Register and update Guide for OBDSTAR X300 DP PAD Key Programmer

The instructions on OBDSTAR X300 DP PAD key programmer registration and upgrade.

Register Guide for OBDSTAR X300 DP PAD Key Programmer:

Step 1:
Connect your VCI with the main cable and the 12V power as follows:
1

Step2:
Turn on tablet and connect with VCI
Situation1— In general, it will connect with VCI automatically after turning on the tablet as follows:
2

Situation2—If your tablet didn’t connect with VCI automatically, please operate as follows:
Click “setting”—Enter “Bluetooth”—Click the Bluetooth name of VCI to connec
3
6

4
5
6

Enter ”DP”—Enter “Setting”—Begin to register—Fill in the registration information—Register succeddfully
7
8
9
10
11

Update Guide for OBDSTAR X300 DP PAD Key Programmer:
Step1.:
Connect WIFI as follows
12
13
14

Step 2.:
Begin to update your device obdstar x300dp
15
16

The update will be finished once all the vehicles have been 100% updated.
17

https://www.gamerlaunch.com/community/users/blog/4750493/1893869/first-time-using-autel-maxisys-ms906

How to register and activate Launch X431 Diagun IV

This post shares you with a guide about how to use Launch X431 Diagun. As the 4 generation of x 431 diagun, this one Diagun IV could use directly without IP limit. It is a useful tool which supports over 20 easy-changeable language as well as new 11 special functions added.

This post will show like this:
1.How to register and activate Launch X431 Diagun IV?
2.How to Connect/Disconnect Diagun IV WiFi?
3.How to set up X431 Diagun IV Bluetooth?

How to register and activate Launch X431 Diagun IV?

User registration

Tap “Login” in the upper right corner of the main menu screen:

6-1

If you are a new user, tap “New Registration”.
6-2

Note: To obtain better service, you need to provide real information.

1.Create App account: In Image 3, fill in the information in each field and then tap “Register”, a screen similar to the following will appear:
6-3

2.Activate the VCI connector: In Image 4, input the Serial Number and Activation Code, which can be found in the password envelope.
6-4

Note: To exit and activate it later, tap “Skip”. In this case, you can activate your connector by tapping “Activate Connector” in “Personal Center”.

Activate Connector.

Download diagnostic software: Tap “Activate”, a dialog box similar to Image 5 will appear:

To download the diagnostic software, tap “Yes” to enter the software download page. Tap “No” to download it later. On the download page, tap “Update” to start downloading. It may take several minutes to finish it, please be patient to wait. To pause downloading, tap “Pause”. To resume it, tap “Continue”. Once the download is complete, the system will install the software package automatically.

If you have registered to be a member, input your name and password, and then tap the “Login” button to enter the main menu screen directly.

Note: launch x431 scan tool Diagun IV has an auto-save function. Once the username and password are correctly entered, the system will automatically store it. Next time you login the system, you will not be asked to input the account manually.

If you forgot the password, tap “Retrieve Password”, and then follow the on-screen instructions to retrieve it.

6-5

How to Connect/Disconnect X431 Diagun IV WiFi?

Note: If you don’t need to use Wi-Fi for a while, you can turn it off to conserve battery life.

X-431 Diagun IV has built-in Wi-Fi that can be used to get online. Once you’re online, you can register your X-431 Diagun IV, surf the Internet, get apps, send email, launch the remote diagnosis, and check for software updates etc.

1.Connect to a Wi-Fi network

1).On the home screen, tap Settings -> WLAN.
2).Slide the Wi-Fi switch to ON, X-431 Diagun IV will start searching for available wireless networks.
3).Select a wireless network, y If the chosen network is open, X-431 Diagun IV will connect automatically; y If the selected network is encrypted, a network password will need to be entered. 4).When “Connected” appears, it indicates the Wi-Fi connection is complete.

Note: When Wi-Fi is not required, this should be disabled to conserve battery power. Once it is connected successfully, tap the Wi-Fi network from the list to view its name, link speed, security type, IP address etc. When this tool is in range, it will connect to the previously linked network automatically.

2.Disconnect from a Wi-Fi network

1).On the home screen, tap Settings -> WLAN.
2).Tap the network with a Connected status, then tap “Disconnect”.

How to set up X431 Diagun IV Bluetooth?

Enter X-431 Diagun IV Bluetooth setting screen (“Settings” -> “Bluetooth”), slide the Bluetooth switch to ON and X-431 Diagun IV will start searching available Bluetooth device, tap the desired connector to pair. By default, the Bluetooth name is 98729*****00 (where ***** stands for 5 digits.).

Note: In case no Bluetooth setting is done before diagnostic software is launched, you can also configure it while using the software.
6-6